    RAYTECH USA, Inc. 118 S. 2 nd  Street Perkasie, PA 18944 USA Tel. 888 4 THE SPY Tel. 267 404 2676 Fax. 267 404 2685 Three Phase Automatic Transformer Turns Ratiometer Test System Model: TR   –  Spy Mark II Instruction Manual Ver. 1.18    Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent Ver 1.18 2 RAYTECH USA, Inc.   0  –   1   T A B L E O F C O N T E N T S Section Page Table of Contents 0  –   1 2  Safety Precautions 1  –   0 3  Uncrating Procedure 2  –   0 4  Introduction 3  –   0 5  Specifications 4  –   0 6  Front Panel Description 5  –   0 7-9  Operation Screens 6  –   0 10, 11  Menu Screens   6  –   1  12 Transformer Ratio Testing  7  –   0 13 Getting Started Quickly 8  –   0 14   Comparison of International Standards 14 WARNINGS! 14 Quick-SPY Basic Training Instructions 15  Operating Instructions 9  –   0 16   Step by Step (Typical) Training Instructions 16 Hooking up to a Transformer 16 Selecting Configurations 17 Phase Displacement Settings 18 Entering Transformer Info. 19, 20 Performing a Test 9  –   4 21   Tap Changer Testing 21 Memory / Archive / Storing Results 22 Printing 22, 25 Language Selection 23 Contrast 23 Current Transformers 10  –   0  24 Test Report 11  –   0 25  Computer Interface (Command Set)  12  –   0 26-32  Troubleshooting 13  –   0 33  Warranty 14  –   0 34    Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent Ver 1.18 3 SAFETY PRECAUTIONS! 1  –   0   The following safety precautions must be observed during all phases of operation, service, and repair of this instrument. By purchasing this equipment the purchaser assumes all liability for the operation and use of this equipment. The intended use of the instrument, its design and manufacture, is to be conducted within the precautions or other specific warnings located within this manual. Failure to comply with these precautions and other specific warnings violates safety standards of design, manufacture, and intended use. Raytech USA, Inc. assumes no liability for the operation and use of this equipment. SAFE OPERATION Only qualified knowledgeable persons should be permitted or attempt to operate this test equipment. All test personnel should fully familiarize themselves with the correct application and operation of this and all test equipment prior to operation. Persons directly and indirectly engaged in the operation of this test equipment should keep clear of all high voltage apparatus while conducting tests and measurements. BEFORE APPLYING POWER Do not vary the input power source voltage level (IE...Connected to a variable AC power source). The TR-SPY MARK II auto-senses the input power from the mains plus from 100 to 240 vac 50/60Hz. Varying the input voltage will cause the test voltage to vary and result in a higher or lower test voltage than indicated. GROUND THE INSTRUMENT To minimize shock hazard, the instrument chassis and cabinet must be connected to a properly grounded receptacle. The power cord supplied with the equipment must be connected an electrical receptacle with an electrical ground (safety earth ground). Non grounded instruments are dangerous and may cause instrument damage. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes. KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified service personnel. Do not replace components with power cable connected. To avoid injuries, always disconnect power, discharge circuits, and remove external voltage sources before touching components. DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to a Raytech USA service department for service to ensure proper operation and that safety features are maintained. Instruments, which appear damaged or defective, should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel.    Raytech USA, Inc. All rights reserved. No portion may be reproduced without written consent Ver 1.18 4 UNCRATING   2  –   0   Unpack your new TR-SPY Mark II and check to see that you have the following items: TR-Spy Mark II Cable bag H lead X Lead 2 Extension Power RS-232 Manual Cable Side Cable Side Cables Cord Cable If any of the above items are missing or damaged contact your local representative or Raytech USA, Inc. immediately. RAYTECH Toll free service & support telephone: 1 888 4 THE SPY * Note 1: The TR-Spy Mark II Fieldcase is a waterproof design that incorporates venting latches that will automatically equalize pressure differential inside the case when opened and seal the case against gas exchange when closed. * Note 2: When the optional hard travel case (part number ST0 822 ) or the optional soft travel case (part number MC845 ) is ordered with a new TR-Spy Mark II, the cable bag depicted above is omitted from the shipping box.
Recommended
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks