EMR-Protection Shielding paints 1/5 Product overview shielding paints are electro-conductive coatings for the protection of large areas from electromagnetic radiation (EMR). They offer best shielding qualities
Transcript
EMR-Protection Shielding paints 1/5 Product overview shielding paints are electro-conductive coatings for the protection of large areas from electromagnetic radiation (EMR). They offer best shielding qualities for protection against high-frequency (HF) radiation and (or) against low-frequency (LF) electric fields. Typical areas of application are living areas (e. g. bedrooms, nurseries, living rooms), or the protection of whole buildings. HSF 54 HSF 55 HSF 65 HSF 91 NSF 34 Shielding HF X X X X Shielding LF X X X X X Brief description Our longtime proven paint Our new universal paint Our lowemission paint Our new silver paint Our longtime proven paint for LF Screening 1-layer 36 db (99.98%) at 7.5 m²/l 27 db (99.8%) at 7.5 m²/l; 27 db (99.8%) at 7.5 m²/l; 47 db (99.998%) at 10 m²/l; 4 / 99 % Screening 2-layers 43 db (99.995%) at 2x 7.5 m²/l 35 db (99.97%) at 2x 7.5 m²/l; 35 db (99.97%) at 2x 7.5 m²/l; Typical application single-layer double-layer double-layer single-layer single-layer Screening basis Carbon Carbon Carbon Pure silver Carbon Color Black Black Black Olive-green Black Application area Interior/Exterior Interior/Exterior Interior Interior/Exterior Interior/Exterior Surface, mechanical Viscoplastic, Hard, Hard, Very hard, Hard, resilience limited resilient normal resilient normal resilient very resilient normal resilient Typical coverage, 1 liter, single-layer Interior: 7.5 m²; Exterior: 5 m² Interior: 7.5 m²; Exterior: 5 m² Interior: 7.5 m² Interior: 12.5 m²; Exterior: 10 m² Interior: 10 m²; Exterior: 7.5 m² Ecology Good Good Very good Normal Good Binding agent Pure acrylic Pure acrylic Acrylate Acrylate Pure acrylic Solvent Water Water Water Water Water VOC content * 0.2 g/l 0.2 g/l g/l 30 g/l 0.2 g/l Water vapor permeability SD ~ 0.1 m SD ~ 0.1 m SD ~ 0.1 m SD ~ 0.1 m Density ca kg/l ca. 1.2 kg/l ca. 1.2 kg/l ca kg/l ca kg/l Interior: Interior: Interior: Interior: Grounding ES + EB; ES + EB; Interior: (ES +) EB; ES + EB; required Exterior: Exterior: ES + EB Exterior: Exterior: ES-A ES-A (ES-A +) EB ES-A + EB Frost resistance 5 frost-, 5 frost-, No / Shipping 5 frost-, 5 frost-, in delivery form / thaw cycles / thaw cycles / under 5 C with thaw cycles / thaw cycles / Shipping warranted Always Always e.g. UPS Express Always Always Delivery sizes 1 / 5 / 20 liter 5 / 20 liter 5 / 20 liter 0.25 / 1 / 5 liter 1 / 5 / 20 liter Shelf life 12 months 12 months 12 months 12 months 12 months 5 liter container, 1-layer ner, 2-layer apner, 2-layer apner, 1-layer ner, 1-layer 20 liter contai- 20 liter contai- 1 liter contai- 5 liter contai- Price per m² shielded area, application plication with plication with application application plus VAT with 7.5 m²/l: 2x 7.5 m²/l: 2x 7.5 m²/l: with 10 m²/l: with 10 m²/l: EUR 7.84 EUR 8,97 EUR 8,97 EUR EUR 4.19 * EU limit value for this product (Cat. A/a): 75 g/l (from 2007) and 30 g/l (from 2010). EMR-Protection Shielding paints 2/5 General Product descriptions HSF54 (Pure acrylic, HF radiation + LF electric fields, Interior + Exterior application) Our longtime proven paint for interior and exterior application. ❶ This paint achieves very high attenuation even at single-layer application. The viscoplastic and soft surface has a limited mechanical resistance. ❷ Low VOC content, highly breathable, free of solvents, plasticisers, etc. ❸ Good adhesion on many interior and exterior surfaces and substrates like old emulsion paint layers, sheetrock, cement, plaster, masonry, wood, etc. Can easily be covered with water based emulsion paint (also known as latex or vinyl paint). ❹ To bridge forming gaps in the underground, this paint is reinforced with long conductive fibers. So especially in outdoor applications no ground-strap is needed for safe grounding. ❺ This paint is frost resistant (tested for 5 freeze / thaw cycles), and can thus be shipped even in wintertime by air cargo or by ship. ❻ Attenuation of 36 db (shielding effectiveness of %) at typical coverage in one layer, attenuation of 43 db (shielding effectiveness of %) at typical coverage with two layers. ❼ Ingredients: Water, pure acylic binder, graphite, carbon black, additives, preservative. HSF55 (Pure acrylic, HF radiation + LF electric fields, Interior + Exterior application) Our new universal paint for interior and exterior application. ❶ Compared to HSF54, this paint contains no graphite, it has a hard, mechanically resilient and adhesion enhancing surface. To achieve a high attenuation, we recommend a two-layer application! ❷ Low VOC content, highly breathable, free of solvents, plasticisers, etc. ❸ Excellent adhesion on many interior and exterior surfaces and substrates like old emulsion paint layers, sheetrock, cement, plaster, masonry, wood, etc. Can easily be covered with water based emulsion paint (also known as latex or vinyl paint). ❹ To bridge forming gaps in the underground, this paint is reinforced with long conductive fibers. So especially in outdoor applications no ground-strap is needed for safe grounding. ❺ This paint is frost resistant (tested for 5 freeze / thaw cycles), and can thus be shipped even in wintertime by air cargo or by ship. ❻ Attenuation of 27 db (shielding effectiveness of 99.8 %) at typical coverage in one layer, attenuation of 35 db (shielding effectiveness of %) at typical coverage with two layers. ❼ Ingredients: Water, pure acylic binder, carbon fibers, carbon black, additives, preservative. HSF65 (Pure acrylic, HF radiation + LF electric fields, Interior application) Our new very low emission paint for interior application. ❶ Compared to HSF54, this paint contains no graphite, it has a hard, mechanically resilient surface with adhesion enhancing properties. To achieve a high attenuation, we recommend a two-layer application! ❷ Very low VOC content due to a new special purified acrylic binder, highly breathable, free of solvents, plasticisers, etc. ❸ Good adhesion on many interior surfaces and substrates like old emulsion paint layers, sheetrock, cement, plaster, etc. Can easily be covered with water based emulsion paint (also known as latex or EMR-Protection Shielding paints 3/5 vinyl paint). ❹ To bridge forming gaps in the underground, this paint is reinforced with long conductive fibers. Nevertheless we always recommend usage of our grounding-strap EB for interior applications. ❺ This paint is not frost resistant! Shipping only in the summer or with UPS Express. ❻ Attenuation of 27 db (shielding effectiveness of 99.8 %) at typical coverage in one layer, attenuation of 35 db (shielding effectiveness of %) at typical coverage with two layers. ❼ Ingredients: Water, acylic binder, carbon fibers, carbon black, additives, preservative. HSF91 (Acrylic, HF radiation + LF electric fields, Interior + Exterior application) Our new paint for interior and exterior application with pure silver as the sole conductive component. ❶ Compared to similar (mostly copper or nickel based) shielding laquers on the market, this paint contains only silver as conductive component, no copper, no nickel etc., so this paint is absolutely corrosion-resistant! This paint has a hard and mechanically resilient surface. ❷ Breathable, low VOC-content for this product group. ❸ Excellent adhesion on many interior and exterior surfaces and substrates like old emulsion paint layers, sheetrock, cement, plaster, masonry, wood, plastics, etc. Can easily be covered with water based emulsion paint (also known as latex or vinyl paint). ❹ To bridge forming gaps in the underground, we recommend the usage of our ground-strap EB. ❺ This paint is frost resistant (tested for 5 freeze / thaw cycles), and can thus be shipped even in wintertime by air cargo or by ship. ❻ Attenuation of up to 5 (shielding effectiveness of %) in one layer. ❼ Ingredients: Water, acylic binder, silver, titanium dioxide, glycols, additives, preservative. NSF34 (Pure acrylic, LF electric fields, Interior + Exterior application) Our longtime proved paint for interior and exterior application. Just like HSF55, but for protection from low-frequency electric fields only and without fiber-arming. Common Characteristics of all Shielding Paints Simple handling and processing shielding paints can be applied universally. The shielding paints are easy to apply, even in structured rooms with bays, pitched roofs and dormers. House painters recommend s shielding paints for ease of application. All shielding paints are applied best with a paint roller. Carefully Selected Ingredients shielding paints do not contain toxic solvents, plasticisers, or any other toxic ingredients; they only contain marginal amounts of VOC containing components. Therefore they are low-emission products and meet the strictest standards for application in Building Biology projects. All ingredients are selected carefully, according to their high quality and their safety for all humans who get in contact with the paint: the factory personnel, the painters applying the paint, and the individuals occupying the rooms shielded with shielding paints Oben: Dünne Verarbeitung (10 qm/l) auf Hartfaserplatte Unten: Dickere Verarbeitung (7,5 qm/l) auf Hartfaserplatte EMR-Protection Shielding paints 4/5 Perfect Corrosion restistance Most shielding products containing metal components are not adequately protected against corrosion. shielding paints are shielding without metal particles using only carbon. Therefore they offer perfect corrosion resistance (no oxidizing) and long-term durability. Security and protection even against future High-Frequency applications Due to its holohedral structure without meshes, all shielding paints offer almost constant attenuation, without preferred direction of polarization, for frequencies of up to 18 GHz. This means: perfect protection against future developments of the telecommunications industry in the higher Gigahertz range is guaranteed, when using our shielding paints. Areas of application Living areas: Protection against HF-radiation from cell phone towers, TV and radio broadcasting antennas, radar, digital standard cordless telephones and wireless networks, etc. Protection against low-frequency electric fields from power supply lines, etc. Industry: To prevent interception of data from wireless networks ( data-stealing ) and to prevent interception of potentially bugged conference rooms. Science and R&D: Shielding of EMI-sensitive facilities and equipment. Medicine: Protection of sensitive technical equipment; to guarantee that important medical data is derived correctly and will not be altered by electromagnetic interference (EMI). Electronic Industry (e.g. recording studios): To reduce induction and interference. Further applications: schools, nurseries, hotel rooms, hospital rooms, etc. Certificate of shielding Tested and certified by the Microwave Laboratory of the University of the German Federal Armed Forces in Munich, Germany. Professor Diploma-Engineer Peter Pauli states: Another remarkable fact is the very constant and almost frequency independent outstanding shielding. Please ask for certificate. Certificate of VOC emissions All of our shielding paints are tested for volatile organic compound (VOC) emissions according to EU standard 2004/42/EG ChemVOCFarbV. This testing is done by an accredited and independent laboratory. Test results are given in the table on page 1. Current limits as prescribed by law are 75 g/l for A/a classified products. s HSF54 boasts a 0.2 g/l VOC value, far below the current limit of 75 g/l, and even beating the stricter limits in effect from 2010, which will be 30 g/l. Common handling and processing instructions Underground / Subsurface: Underground needs to be solid, clean, degreased and dry. Interior: Shielding paints may be applied over existing emulsion paint, wallpaper, construction boards, cement, plaster, etc. Exterior: Shielding paints may be applied on concrete, plaster, cement, facade emulsion paint, polystyrene, masonry surfaces, etc. Strongly absorbent or porous surfaces are to be prepared with a prime coat. Application: Best use a paint roller. Minimum application temperature: (MFFT) +5 C / 41 F. Covering of shielding paint / Top coat: Depending on environment temperature and humidity paint needs hours to dry. The surfaces of shielding paints have to be protected against mechanical exposure. Interior: Cover with typical emulsion or vinyl paint with good hiding power. Exterior: Cover with hydrophobic emulsion facade paint. NOTE: Do not cover with silicate paints, plasters, mortars, etc. (applies for interior + exterior paint)! EMR-Protection Shielding paints 5/5 Accessoires for Grounding / Earthing Depending on local regulations, e.g. the DIN-Code in Germany, grounding requires a licensed electrician. Please be sure to follow all local laws and standards. To ensure good ground connection of the shielding paint coat, we recommend for interior use Ground-Connection-Set ES in combination with Ground-Strap EB. For exterior use we recommend 2 Ground-Connection-Sets ES-A. Ground-Connection-Set ES interior Ground-Connection-Set for all Shielding Paints. Ground-Connection-Set ES is specifically designed to guarantee proper grounding of the shielding paint coat. For each connected area (or surface) of shielding paint coat, one Ground-Connection-Set is required! High-grade steel plate 8 x 8 x 0.3 cm with conductive fleece backside; 4 Stainless steel screws, 4 dowels / wall plugs ø 6 mm; 1 m grounding cable ø 2.5 mm²; Ground-Strap EB interior Ground-Strap for shielding paints for interior use. All areas / surfaces shielded with shielding paints need to be grounded for personal protection. In case of cracks forming in the walls, which would possibly disconnect grounding for parts of the painted surfaces, the ground strap will secure grounding even for those parts which are disconnected from the grounding / the ground plate due to the crack(s). Therefore, ground strap is to be applied uninterrupted, in one piece on all shielded surfaces, to secure good ground connection in case of cracks in walls, etc.; Self-adhesive strap with highly conductive silver-containing glue; 100% corrosion resistant copper strap, tin-coated on both sides; Length 10 m, width 2 cm, thickness 0.06 mm. Ground-Connection-Set ES-A exterior Ground-Connection-Set for all Shielding Paints. Ground-Connection-Set ES-A is specifically designed to guarantee proper grounding of the shielding paint coat in exterior applications. We recommend to use one ground connecton set ES-A (or two sets for added security) for each connected surface / connected area of shielding paint coat in outdoor shielding applications. High-grade steel plate 8 x 8 x 0.3 cm with conductive fleece backside; Mounted IP65-casing; 4 Stainless steel screws, 4 dowels / wall plugs ø 6 mm; 1 m grounding cable ø 16 mm²;
Recommended
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks